Each generator's ON/OFF states describe the current diesel-only system—not the optimized hybrid systems.
Up to 6 generators
03 · Solar hybrid backup generator
A different operating plan from the diesel baseline. Starts with an automatically suggested schedule.
Diesel + BESS + PV
Solar ON/OFF schedule — starts from a suggested pattern (generator ON during hours without solar production). Edit any hour to recalculate.
Advanced technical and economic inputs
Detailed configuration
Transparency and replaceable reference data
Model assumptions
These are screening assumptions, not independently verified quotations or manufacturer guarantees.
Methodology & sources
Generator Load Vs Consumption
Where manufacturers do not disclose fuel consumption at low loads, values are estimated using data from comparable generators. Fuel consumption is interpolated between the 0%, 25%, 50%, 75%, and 100% load breakpoints. In the diesel baseline, all active generators use the same hourly loading fraction.
Rental Pricing
Generator rentals in USD are reference estimates, not verified quotations.
Maintenance Model
The maintenance cost entered in Detailed Configuration represents an average under good operating conditions, with generators operating between 50% and 75% load. Estimated maintenance costs increase as generator loading decreases.
Solar Irradiation
Site-specific irradiation, panel orientation, seasonal weather, and system degradation require detailed analysis.
!Results are preliminary engineering screening only.
Generator models & hourly fuel curves
Editable rental assumptions
Add a generator model
Add your own generator with rated power, fuel curve and rental price.
BESS equipment reference
Energy and power
Add a BESS model
Solar assumptions · reference region
GHI · kWh/m²/day
U.S. 2024 state-level solar assumptions. Edit GHI if you have better location-specific data.
HSP médio estadual estimado. Usuário pode alterar com dados locais. Perfil horário estimado.
Compare hybrid alternatives → understand savings
Assessment results
Diesel-only reference compared with two alternative operating strategies. All results are modeled screening estimates.
Monthly operating cost comparison
Turn this screening into a decision
AgilTS validates these numbers against your real load data, equipment quotes and site constraints, and helps plan the move from diesel-only to hybrid power.
Prepared with the AGILTS Hybrid Energy Calculator · Preliminary screening estimate · agilts.solutions · [email protected]
Diesel + BESS power flow
Diesel + BESS + PV power flow
Privacy & optional usage analytics
Analytics is off by default. If enabled and a Cloudflare D1 database is connected, we count this tab's first visit, calculation requests, report actions (save/export/print), and clicks on the email contact link. A calculation request is not a unique person or project. New events do not include load profiles, equipment inputs, IP addresses, or countries. Historical events collected by older releases may still exist until deleted. Events are deleted after approximately 90 days when tracking remains active.
Referral attribution is separate and disabled by default. The tag is not saved without this permission.
Optional usage counters are off; no activity is recorded.
Disable the checkbox to stop future tracking. Questions or deletion requests: [email protected].